Study guide

11.2 Manufactured Homes, Campgrounds, RV Parks & Dump Stations

Wisconsin Journeyman Plumber Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Licensing, Exam Rules & Code Administration

1.1 Wisconsin Plumbing Credentials, Scope & Supervision (Ch. 145, SPS 305) 1.2 The Journeyman Exam: Format, Fees, Retakes & Permitted References 1.3 Plan Review, Plan Approval & Product Approvals (SPS 382.20) 1.4 Testing, Inspection, Maintenance & Repairs (SPS 382.21, 382.22) 1.5 Code Structure, Key Definitions, Basic Principles & Referenced Standards

2 Chapter 2: Sanitary Drainage Systems (SPS 382.30)

2.1 Drainage Fixture Units (DFU) & Load Values 2.2 Horizontal Branch Drains, Pitch & Changes in Direction 2.3 Drain Stacks, Branch Intervals & Stack Offsets 2.4 Building Drains, Building Sewers & Private Interceptor Main Sewers

3 Chapter 3: Venting Systems & Cold-Climate Vent Terminals (SPS 382.31)

3.1 Vent Stacks, Relief Vents & Vent Sizing Tables 3.2 Common Vents, Wet Vents & Circuit Vents 3.3 Return Vents, Combination Drain & Vent Systems & Air Admittance Valves 3.4 Vent Terminals, Frost Closure & Prohibited Vent Uses

4 Chapter 4: Traps, Indirect Waste & Wastewater Treatment Devices

4.1 Fixture Traps, Trap Seals & Direct Fixture Connections 4.2 Trap-to-Vent Distances (Table 382.31-1) 4.3 Indirect & Local Waste Piping, Air Gaps & Receptors 4.4 Interceptors, Catch Basins & Chemical Waste Treatment (SPS 382.34)

5 Chapter 5: Water Supply Systems (SPS 382.40)

5.1 Water Supply Fixture Units (WSFU) & Demand 5.2 Sizing Water Distribution Piping: Pressure, Friction & Velocity 5.3 Control Valves, Thermal Expansion, Water Hammer & Pipe Identification 5.4 Water Heaters, Relief Valves, Hot Water Delivery & Temperature Control 5.5 Water Services, Private Water Mains, Disinfection & Storage Tanks

6 Chapter 6: Cross-Connection Control & Backflow Prevention (SPS 382.41)

6.1 Cross-Connection Fundamentals, Hazard Classes & Pressure Conditions 6.2 Backflow Devices & Assemblies: Table 382.41-1, Limits & Installation 6.3 Assembly Registration, DSPS Tags, Annual Testing & Tester Registration

7 Chapter 7: Plumbing Fixtures, Fittings & Appliances (SPS 384.20)

7.1 Fixture Construction, Clearances, Shower Size & Safing 7.2 Water-Conserving Fixtures, Faucets & Fixture Supply Connectors 7.3 Water Heaters, Water Treatment Devices & Other Plumbing Appliances

8 Chapter 8: Piping Materials, Joints & Supports (SPS 384.30, 384.40, 382.60)

8.1 Approved Piping Materials by Service & Lead-Free Rules 8.2 Joints, Connections & Transitions Between Materials (SPS 384.40) 8.3 Hangers, Supports & Protection of Piping (SPS 382.60)

9 Chapter 9: Private Onsite Wastewater Treatment Systems (SPS 383, 385 & Component Manuals)

9.1 POWTS Regulation, Sanitary Permits, Plan Review & Inspection 9.2 Soil & Site Evaluation and In Situ Soil Parameters (SPS 385, SPS 383.44) 9.3 Design Flow, Septic & Holding Tanks and Tank Construction 9.4 Dispersal Components & the DSPS Component Manuals 9.5 POWTS Setbacks, Management, Maintenance Reporting & Abandonment

10 Chapter 10: Cleanouts, Stormwater, Sumps & Multipurpose Piping

10.1 Cleanouts & Manholes (SPS 382.35) 10.2 Stormwater & Clearwater Systems (SPS 382.36) 10.3 Sanitary Sumps, Ejectors & Discharge Points (SPS 382.30 (10), 382.38) 10.4 Multipurpose Piping Systems & NFPA 13D Residential Sprinklers

11 Chapter 11: Special Plumbing Installations & Water Reuse

11.1 Health Care & Related Facilities (SPS 382.50) 11.2 Manufactured Homes, Campgrounds, RV Parks & Dump Stations 11.3 Water Reuse, Plumbing Treatment Standards & Stormwater Infiltration

11.2 Manufactured Homes, Campgrounds, RV Parks & Dump Stations

Key Takeaways Explain This Topic AI

A manufactured home water service terminates at least 6 inches above grade, and its sanitary and storm sewers at least 4 inches above grade but no higher than the water service.

Frost sleeves on manufactured home connections extend to within 6 inches of the buried horizontal pipe or 6 inches below frost depth and end at least 2 inches above grade.

A manufactured home drain connector has a minimum slope of 1/8 inch per foot; a manufactured home is rated at 11 dfu and 15 wsfu.

A campsite receptor is at least 4 inches, serves no more than 4 RVs, has a rim at least 4 inches above grade, needs no trap vent and is capped when unused.

A sanitary dump station has a 4-inch receptor with a hands-free self-closing cover, a 6-foot impervious pad sloped 1/4 inch per foot, and a labeled nonpotable washdown supply at least 50 feet from potable supplies.

Last updated: October 2026

Licensing and plan review

Restricted-service licensees and learners may install manufactured home community and campground or RV park water supply and drain systems, and the connection from the sewer or water service to the home manufacturer's connection (SPS 305.90 (1) (b) 1.).

Water supply and drain systems for manufactured home communities and campgrounds are on Table 382.20-2 line 6. Only agent municipalities that are cities of the first class may review them; otherwise DSPS does. Sanitary dump stations are on line 4.

Manufactured home connections use these load values: 11 dfu (Table 382.30-1), 15 wsfu (Table 382.40-1b), and 20 psig minimum flow pressure at the home's supply (SPS 382.40 (7) (d)).

  • Manufactured homes and communities (SPS 382.51)
  • Sanitary drain systems
  • Rule Requirement
  • Design basis Building sewer provisions of SPS 382.30
  • Drain connector Minimum slope 1/8 inch per foot ; aboveground drain material (SPS 384.30 (2) (a))
  • Sewer and community drain material Sanitary building sewer pipe (SPS 384.30 (2) (c))
  • Upstream point of the sewer Its connection with the home's drain connector
  • Termination Above surrounding finished grade
  • Cleanouts Per SPS 382.35, plus one where more than one home is served by a single drain
  • Locating Tracer wire or GPS for nonmetallic drains to municipal mains
  • Testing As building sewers and private interceptor main sewers
  • Water supply systems
  • Rule Requirement
  • Downstream point of the water service Connection with the manufacturer's water distribution piping
  • Service and community main material Water service and private main material (SPS 384.30 (4) (d))
  • Home water connector Water distribution material (SPS 384.30 (4) (e))
  • Curb stop For each home, terminating outside the home's perimeter
  • Building control valve At least 6 inches above grade on the service or community supply
  • Flushing Designed for periodic flushing at 3 ft/s (AWWA C651)
  • Testing As water services and private mains
  • Connections at the home (SPS 382.51 (3))

Frost sleeves on water, sanitary and storm risers extend to within 6 inches of the top of the buried horizontal pipe, or at least 6 inches below predicted frost depth. They end at least 2 inches above grade and are made of building drain or sewer material.

Terminations : water at least 6 inches above grade; sanitary and storm at least 4 inches above grade and not higher than the water termination .

All connections are capped or plugged when no home is connected.

Worked example. A new manufactured home pad: the water riser ends 8 inches above grade, the sanitary riser 6 inches and the storm riser 5 inches. Water is at least 6, the drains at least 4, and neither drain is higher than the water, so all comply. If the sanitary riser were cut at 10 inches, it would be higher than the water riser and would fail.

  • Campgrounds and RV parks (SPS 382.37 (3))
  • Sanitary drain systems

Each RV drain line discharges to a campsite receptor of at least 4 inches through an indirect waste pipe.

One receptor serves no more than 4 RVs . If 2 or more drain lines share a receptor, install an increaser in the vertical standpipe.

Receptor rim at least 4 inches above grade, and not higher than the site's water supply termination.

No vent is required for the campsite receptor trap, which may sit below frost depth (SPS 382.32 (4) (b) 1. d.). Campsite receptors are 6 dfu with a 4-inch trap.

Cap receptors when not in use.

Use building sewer materials. Add a cleanout upstream of where more than one receptor joins a single drain.

Provide tracer wire or GPS, and test as a building sewer.

Pitch per Table 382.30-3 (SPS 382.30 (5) (d)).

Water supply systems

An accessible control valve at the most upstream point, downstream of the municipal meter or pressure tank.

Individual backflow protection at each campsite hose connection. Hose connection vacuum breakers may be used under continuous pressure only at campgrounds and marinas (SPS 382.41 (4) (c)).

Campsite water risers end at least 18 inches above grade.

Site water may serve only that campsite.

A camping unit may be plumbed directly if its fixtures meet chs. SPS 382 and 384, or connected by NSF/ANSI 51 or 61 hose with individual backflow protection.

Campsite hose connections need at least 15 psig flow pressure.

Design for flushing at 3 ft/s, test as water services, and provide a locating method.

Sanitary dump stations (SPS 382.37 (2))

  • Item Requirement
  • Receptor At least 4 inches , trapped; vented if inside an enclosed structure
  • Cover Self-closing and operable without touching it with one's hands
  • Pad Impervious, at least 6 feet in diameter, sloped 1/4 inch per foot to the receptor

Washdown water Permanent supply with backflow protection, labeled not for drinking, at least 50 feet from a potable supply unless a variance is approved

  • Trap May sit more than 3 feet below the receptor opening to reach below frost
  • Water-carried composting systems (SPS 382.37 (1))

Composting toilets that use water or another liquid to carry waste meet NSF 41 , are listed, and are continuously ventilated, with vents terminating like plumbing vents. End product disposal follows 40 CFR Part 503. Liquids go to a public sewer or a POWTS, and the potable supply connection is protected under SPS 382.41. Dry composting toilets fall under ch. SPS 391 instead.

Loading diagram... Manufactured home and campsite connections